Page number 1

Wire spiral hoses - Spiralfit Hose dim. 3/4" 1" 1.1/4" 1.1/2" 2" 1.1/4" 1.1/2" 2" Ferrule type 65950-12 -16 -20 -24 -32 65952-20 -24 -32 Marking M05400-12 M05400-16 M05400-20 M05400-24 M05400-32 M05500-20 M05500-24 M05500-32 Diam X length before crimping 43,8 x 53,5 52,0 x 64,3 59,3 x 72,0 68,5 x 78,0 84,6 x 97,1 66,0 x 70,0 75,0 x 79,0 90,0 x 98,1 Note SF SF SF SF SF SF SF SF Crimping chart 547 548 549 5595 53420 55280 55350 55420 36,7 36,7 37,3 36,7 36,4 36,4 44,4 44,5 45,1 44,5 44,1 43,9 44,1 52,0 51,7 51,8 59,7 59,4 75,8 74,7 57,2 57,9 57,6 57,6 54,8 65,8 65,8 65,2 79,8 79,3 References and explanations for the crimping chart: Abbrevations used under column “note” in the chart describes which insert category the ferrule shall be used with. Combinations of ferrule and inserts from different categories and different manu - factures are not permitted. Please see http://intranett.tessdata.no for updated version of crimp- ing chart. Contact your nearest TESS Service centre if you have questions. Reservations for typing error and changes. Crimping control steps Step 1. Inspect the crimping dimension in the die-set area as indicated in the picture. Take four measurements across the crimped ferrule at 45° to each other using a vernier calipers in the middle section of the crimped length of the ferrule. Verify that all four measurements are according to the designated crimping diameter. Tolerance 0/-0,2 mm. Step 2. Inspect the crimp taper values Measure the diameter at the top of the ferrule and at the bottom of the ferrule (see picture) Verify that the ferrule taper satisfies the following limits: Taper ≤ 0,3 mm. for hose size up to and including 5/8 inch Taper ≤ 0,6 mm. for hose size from 3/4 inch up to and including 3 inch Marketing/bvs/28.05.2021

    ...